Показать сокращенную информацию
dc.contributor.author | Ashkey, E. | |
dc.contributor.author | Zhussupbekov, A.Zh. | |
dc.contributor.author | Dosmukhambetova, B.K. | |
dc.date.accessioned | 2023-06-01T08:07:29Z | |
dc.date.available | 2023-06-01T08:07:29Z | |
dc.date.issued | 2020 | |
dc.identifier.issn | 2616-7263 | |
dc.identifier.uri | http://rep.enu.kz/handle/enu/1339 | |
dc.description.abstract | The International Exposition took place in 2017 in Nur-Sultan, Kazakhstan as The EXPO 2017 on Future Energy. This project has Center of the Arts, Energy Hall and even a city with an indoor shopping and entertainment pavilions. EXPO complex occupies 173.4 hectares. The leading construction companies built the «city of the future». Foundation of the EXPO 2017 project was constructed by modern geotechnologies in Nur-Sultan, Kazakhstan. O-cell loading test and conventional static tests were conducted and compared their results. O-cell testing method was studied and described advantages of using it for large diameter pile foundations. The O-cell test method offers a number of potential advantages versus the conventional testing of bored piles, such as economy, high load capacity, shear/bearing components, improved safety, rock sockets and reduced work area. | ru |
dc.language.iso | en | ru |
dc.publisher | L.N.Gumilyov Eurasian National University | ru |
dc.subject | O-cell test | ru |
dc.subject | static loading test | ru |
dc.title | Analysis of O-Cell Loading Piling Test at construction site of Expo 2017, Nur-Sultan, Kazakhstan | ru |
dc.type | Article | ru |