DSpace Repository

IDENTIFYING THE INFLUENCE OF THE SYSTEM AND MODE CHARACTERISTICS ON THE POWER LOSS MODE BASED IN 110 kV POWER GRIDS

Show simple item record

dc.contributor.author Akimzhanov, Temirbolat
dc.contributor.author Sarsikeyev, Yermek
dc.contributor.author Zhantlessova, Assemgul
dc.contributor.author Zhumazhanov, Serik
dc.contributor.author Baydulla, Zhanibek
dc.contributor.author Issabekova, Bibigul
dc.contributor.author Issabekov, Zhanat
dc.contributor.author Mekhtiyev, Ali
dc.contributor.author Neshina, Yelena
dc.date.accessioned 2024-09-10T04:34:50Z
dc.date.available 2024-09-10T04:34:50Z
dc.date.issued 2023-12
dc.identifier.citation Akimzhanov, T., Sarsikeyev, Y., Zhantlessova, A., Zhumazhanov, S., Baydulla, Z., Issabekova, B., Issabekov, Z., Mekhtiyev, A., Neshina, Y. (2023). Identifying the influence of the system and mode characteristics on the power loss mode based in 110 kV power grids. Eastern-European Journal of Enterprise Technologies, 6 (8 (126)), 6–14. doi: https://doi.org/10.15587/1729-4061.2023.292253 ru
dc.identifier.issn 1729-3774
dc.identifier.other DOI: 10.15587/1729-4061.2023.292253
dc.identifier.uri http://rep.enu.kz/handle/enu/16133
dc.description.abstract In this paper, the object of the research is 110 kV power grids of three regions of the Republic of Kazakhstan: Astana city, Turkestan region and Shymkent city, as well as West Kazakhstan region. Operators of the studied power grids have no idea about the real levels of voltage and current sinusoidality distortion coefficients, as well as about their relationship with other regime and system parameters of power grids. Similar problems may be faced by other grid companies that do not have the appropriate information and measurement infrastructure to monitor the modes of power grids in terms of voltage and current sinusoidality distortion. In the course of the present study, using portable three-phase power quantity and quality analyzers, it was possible to make daily measurements of mode parameters in 41 110 kV transmission lines with a length of 5 to 120 km. The results of measurements showed that in Astana city, the voltage quality is at a satisfactory level, but the distortion coefficient of sinusoidality of current reaches 39 % (the average level for 15 studied lines is 13.3 %) due to the high concentration of non-linear load of consumers. In the South of Kazakhstan, the voltage and current sinusoidality distortion coefficients are relatively moderate, but voltage drops are frequent (sometimes up to 10 % or more) due to the large distance between load centers and relatively high population density. In the power grids of Western Kazakhstan, voltage and current sinusoidality distortion coefficients have high levels (reach 14 % and 70 %, respectively) due to low network load with a large length of transmission lines. The analysis makes it possible to trace the relationship of voltage and current sinusoidality distortion coefficients with such regional characteristics as population density, nature of loads, power losses, voltage and current levels ru
dc.language.iso en ru
dc.publisher Eastern-European Journal of Enterprise Technologies ru
dc.relation.ispartofseries Vol. 6;No. 8 (126)
dc.subject electrical measurements ru
dc.subject power losses ru
dc.subject harmonic distortions ru
dc.subject electric power ru
dc.subject energy efficiency ru
dc.title IDENTIFYING THE INFLUENCE OF THE SYSTEM AND MODE CHARACTERISTICS ON THE POWER LOSS MODE BASED IN 110 kV POWER GRIDS ru
dc.type Article ru


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account