DSpace Repository

Study of the Sensitivity Limit of Detection of α-Particles by Polymer Film Detectors LR-115 Type 2 Using X-ray Diffraction and UV-Vis Spectroscopic Methods

Show simple item record

dc.contributor.author Yerimbetova, Dana S.
dc.contributor.author Kozlovskiy, Artem L.
dc.contributor.author Tuichiyev, Umitali N.
dc.contributor.author Zhumadilov, Kassym S.
dc.date.accessioned 2024-09-24T12:21:42Z
dc.date.available 2024-09-24T12:21:42Z
dc.date.issued 2023
dc.identifier.citation Yerimbetova, D.S.; Kozlovskiy, A.L.; Tuichiyev, U.N.; Zhumadilov, K.S. Study of the Sensitivity Limit of Detection of α-Particles by Polymer Film Detectors LR-115 Type 2 Using X-ray Diffraction and UV-Vis Spectroscopic Methods. Polymers 2023, 15, 2500. https://doi.org/10.3390/ polym15112500 ru
dc.identifier.issn 0171-709X
dc.identifier.other doi.org/10.3390/polym15112500
dc.identifier.uri http://rep.enu.kz/handle/enu/16926
dc.description.abstract This work is devoted to the applicability assessment of optical spectroscopy and X-ray diffraction methods to establish the lower detection limit for the density of latent tracks from αparticles in polymer nuclear-track detectors, in the case of simulation of the formation of radon decay daughter products using Am-241 sources. During the studies, the detection limit for the density of latent tracks—traces of the interaction of α-particles with the molecular structure of film detectors— was established using optical UV spectroscopy (104 track/cm2 ) and X-ray diffraction (104 track/cm2 ). At the same time, analysis of the connection between structural and optical changes in polymer films indicates that a growth in the density of latent tracks above 106–107 results into the formation of an anisotropic change in the electron density associated with distortions in the molecular structure of the polymer. An analysis of the parameters of diffraction reflections (the position and width of the diffraction maximum) showed that in the range of latent track densities of 104–108 track/cm2 , the main changes in these values are associated with deformation distortions and stresses caused by ionization processes during the interaction of incident particles with the molecular structure of the polymer. The increase in optical density, in turn, is caused by the accumulation of structurally changed regions (latent tracks) in the polymer as the irradiation density increases. A general analysis of the obtained data showed good agreement between the optical and structural characteristics of the films depending on the irradiation density ru
dc.language.iso en ru
dc.publisher Polymers ru
dc.relation.ispartofseries 15;2500
dc.subject solid-state nuclear track detectors LR-115 type 2 ru
dc.subject α-particles ru
dc.subject optical spectroscopy ru
dc.subject X-ray diffraction ru
dc.subject radon decay products ru
dc.subject dosimetry ru
dc.title Study of the Sensitivity Limit of Detection of α-Particles by Polymer Film Detectors LR-115 Type 2 Using X-ray Diffraction and UV-Vis Spectroscopic Methods ru
dc.type Article ru